Hello selhosted, First time posting here, I hope I’m not too much off topic !

I am currently working on my homeserver. I needed some more storage, but said server being a tiny Thinkcentre I needed to get a PCIe card to connect 4+ drives to it. I went with a PCIe LSI SAS 3008e card instead of a PCIe to SATA3, mainly because it allowed me to get to 12GB/s and also because the external mini-SAS connector seemed more reliable and stronger than standard SATA3 cables.

I plugged everything and technically it did work great. Until I almost burnt myself while touching the card. Thermometer on the picture failed to report how hot it actually was because I could not find the right place to put the sensor, but it really did felt like it was above 100°C/212°F. Even without touching directly the radiator, I could not keep my finger anywhere on the card either.

I knew nothing about SAS cards before, needless to say I’m a bit disappointed :( And my Thinkcentre is also too narrow to let me to put a fan on the card, so now I feel like I just got myself a new paperweight haha.

Are SAS cards always running this hot? Or did I bought a bad model? Also for those like me who are running their homelab with tiny computers, how did you achieve connecting 4+ drives to it ?

Thank you for reading!

    • esperal@pawb.socialOP
      link
      fedilink
      English
      arrow-up
      2
      ·
      14 hours ago

      Sadly I don’t :( I tested with a spare 4010 and it blocks the lid from closing

      • frongt@lemmy.zip
        link
        fedilink
        English
        arrow-up
        2
        ·
        edit-2
        11 hours ago

        If you’re not worried about aesthetics, you could cut a hole in the case or just leave it off.

        Even if you put a blower fan, you’d need to drill holes so that could actually pull air from the side, like with the other one. Blocking its intake means it’ll do nothing but generate its own heat.

        Edit: also, while these cards are pretty tolerant of heat so as not to die, they will definitely misbehave and cause data errors while above normal operating temps.

        • Guiorgy@lemmy.ml
          link
          fedilink
          English
          arrow-up
          1
          ·
          4 hours ago

          Interesting idea, might be worth expanding the thought and 3D printing a guide duct to redirect some of the airflow to the SAS card