I have two fridge/freezers and a chest freezer. None of them are “smart” and all use mechanical controls. A few months ago I put all three on zigbee plugs, and created an automation to monitor and notify via ntfy if it detects any problems:

  • Notify if compressor doesn’t switch between on/off state for two hours (Based on power usage, detects stuck thermostat, door left open, defrost cycle issue, failed compressor, plug fallen out the socket or anything else which causes the fridge to not run normally). This uses a helper binary sensor which shows “on” if power usage > 40W and fires the notification if the state of the binary sensor doesn’t change for more than 2h.

  • Notify if any of the plugs are turned off or go offline for more than 15 minutes. (This is what fired overnight)


Just after midnight, I was woken by a notification saying two of them had gone offline at the same time. Got out of bed to check and found the RCD breaker feeding two of them had tripped. Isolated the fault to the kitchen fridge, it trips the breaker the moment it is turned on. Left the kitchen fridge unplugged and transferred the contents to the other two plus a spare in the garage. Without this automation it’s likely I wouldn’t have found this problem until the following evening after work when it would have been too late.

Interested to hear if anyone else does similar monitoring using their HA?

  • Parafaragaramus@infosec.pub
    link
    fedilink
    English
    arrow-up
    1
    ·
    30 minutes ago

    Water sensor near the washer that alerts me and turns off the washer. Saved my bacon when the pump housing broke

  • Mikelius@lemmy.ml
    link
    fedilink
    English
    arrow-up
    17
    ·
    13 hours ago

    My save was a leak sensor. I put one below the water softener which triggers an alarm off it detects water and will shut the valve to the house too. The day before a 3 month trip, the alarm went off and we saw we had a huge leak in the back of the softener. Had to shut off the water to the house before we left, but man that could have been horrible to come home to.

  • tiptoes@sh.itjust.works
    link
    fedilink
    English
    arrow-up
    25
    ·
    17 hours ago

    I use two temperature sensors. One directly under the freezer, another on a cabinet beside the freezer at the same height.

    Normally their temperatures are very close, the freezer one less than 1C lower than the control. If the door doesn’t seal fully (door closed but seal is not fully closed due to obstruction or other reason), the difference quickly increases and HA sends a “Door Open” alert.

    It’s sensitive enough to detect even small misalignments, and more reliable than the door close alarm built in the fridge.

  • czardestructo@lemmy.world
    link
    fedilink
    English
    arrow-up
    14
    ·
    16 hours ago

    My wife notoriously keeps leaving the basement freezer door adjar. So I drilled a hole in the top of the freezer, stuffed in a temp sensor, sealed it up and connected it to a pi. Pushes data via Mqtt to HASS so now it harasses both of us if the temp gets above a certain threshold.

      • czardestructo@lemmy.world
        link
        fedilink
        English
        arrow-up
        6
        ·
        9 hours ago

        Sorry I meant only the temp sensor passes through into the freezer, the wire continues up and out to the pi outside the freezer and I sealed the hole and wire with RTV.

  • Onomatopoeia@lemmy.cafe
    link
    fedilink
    English
    arrow-up
    9
    ·
    17 hours ago

    Excellent.

    I’m not using HA for this, but I added temp monitoring for my freezer - unfortunately not self hosted, but has saved me a couple times in the last 3 years.

    Is there a recommended approach to using HA for temp monitoring?

    • Badabinski@kbin.earth
      link
      fedilink
      arrow-up
      2
      ·
      2 hours ago

      I set up a bunch of BLE proxies (ESP32 boards you can flash with a very simple web page which forward Bluetooth stuff to your HA server) and then peppered my house with cheap and cheerful BLE H/T sensors. I also set up ZigBee and use very cheap ZigBee sensors for heterogeneity (so it doesn’t matter if either ZigBee or BLE proxies have issues, things still function as long as one of the two is working).

      Then, as others have said, you can set up automations to do whatever you want for notification or remediation.

    • Freeposity@lemmy.world
      link
      fedilink
      English
      arrow-up
      4
      ·
      17 hours ago

      Buy or make a temp sensor that will work in your freezer and then add automations as needed. It’s probably one of the simplest things to do other that adding a smart bulb to HA.

      • Trilogy3452@lemmy.world
        link
        fedilink
        English
        arrow-up
        6
        ·
        17 hours ago

        Also if you want full DIY: Adafruit sells DIY friendly hardware, a lot of chips have a stemma qt board which means you don’t need to solder anything(as long as the microprocessor board also has stemma qt).

        Ofc you’ll need to write the code, but it’s usually simple enough with examples.

          • David From Space@geostationary.orbiting.observer
            link
            fedilink
            English
            arrow-up
            2
            ·
            4 hours ago

            Nope, never needed to watch those, but it’d be interesting to set up! I just run an airstone in the winter - between that, the ridiculous amount of hornwort, and my bog filter, there is just no chance of poor aeration. I do have sensors & automations to check for the bog flow and turning on the anti-raccoon electric fence though!

            • Freeposity@lemmy.world
              link
              fedilink
              English
              arrow-up
              2
              ·
              2 hours ago

              My problem isn’t racoons, it’s mink. The best defense I’ve had is to let the pond freeze over with a small deicer but that doesn’t always work out. If I had an O2 sensor in the water last year I wouldn’t have lost all my fish and frogs to asphyxiation.

              This year I’m letting the waterfall run to keep the water aerated, spraying wolf urine around the pond and running talk radio 24/7.

              Fingers crossed.

  • SayCyberOnceMore@feddit.uk
    link
    fedilink
    English
    arrow-up
    6
    ·
    16 hours ago

    Not thought of using power monitoring for the fridge / freezer (I’m using temperature instead)

    I do have a simple dehumidifier which seized it’s fan and was drawing several amps. So I replaced the fan and put a 2A safety limit on it’s power monitoring socket.